TECHNICAL DATA: | ||||
Temperature range | up to 130°C with water | |||
Temperature control | self-optimizing, electronic microprocessor controller MP-888 with digital display of the set and actual value. Automatic temperature monitoring. |
|||
Flow control | electronically, with digital display and automatic control of the minimum flow. | |||
Heating capacity Switchable in stages |
48 kW 8 / 8 / 8 / 8 / 8 / 8 automatic shut down of the heating capacity which is not required. |
|||
Cooling capacity | increased cooling capacity by switching to the plate heat exchanger standard heat exchanger approx. 180 kW at 130°C plate heat exchanger approx. 400 kW at 70°C |
|||
Pump capacity Pressure mode |
motor 4kW max 4,5 bar / max. 250 l/min |
|||
Filling | automatic | |||
Connections Medium Cooling water |
female thread flange DN-25 1 1/2″ BSP female thread |
|||
Dimensions (L×W×H) | 1’710 × 790 × 1’540 mm | |||
Weight | approx. 650 kg (empty) | |||
Colour | silvergrey RAL 7001 |
Options:
MP-988 Microprocessor Controller for Digital Interfaces (RS-485 / RS-232 / Current Loop 20mA / CAN-bus / Profibus)
All possible voltages are available from 3 x 200 V to 3 x 600 V and 50/60 Hz.
The units are available conform to UL/CSA specifications. For the USA market the units are equipped with NPT-thread connections and the controller is adjusted to indicate °F
There are no reviews yet.