TT-410 X

Heating and Cooling Unit
Unit for double walled vessels and reactors
Operational use from -20°C up to 240°C

48kW heating capacity     reactor volume: 50 – 400 litres

TECHNICAL DATA:
Temperature range -20°C up to +240°C with heat transfer liquid
Temperature control self-optimizing, electronic microprocessor controller MP-888 with digital display of the set and actual value.
Automatic temperature monitoring.
Flow control electronically, with digital display and automatic control of the minimum flow.
Heating capacity
Switchable in stages
48 kW
8 / 8 / 16 / 16
Cooling capacity
Cooling 1
Cooling 2
150kW at  230°C
175kW at 80°C
Pump capacity
Pressure mode
motor 4,0 kW
max. 4,0 bar
max. 230 l/min
Expansion tank capacity 96 litres
Filling Amount 75 litres
Expansion volume 75 litres
Connections
Oil circuit
Cooling water
Water-glycole
Air pressure
flange DN32/PN16
1 1/2″ BSP female thread
1 1/2″ BSP female thread
min. 5 bar
Dimensions (L×W×H) 1’710 × 790 × 1’540 mm
Weight approx. 590 kg empty
Colour silvergrey RAL 7001


Options:
MP-988 Microprocessor Controller for Digital Interfaces (RS-485 / RS-232 / Current Loop 20mA / CAN-bus / Profibus)

All possible voltages are available from 3 x 200 V to 3 x 600 V and 50/60 Hz.
The units are available conform to UL/CSA specifications. For the USA market the units are equipped with NPT-thread connections and the controller is adjusted to indicate °F.

There are no reviews yet.

Be the first to review “TT-410 X”