TECHNICAL DATA: | cold water circuit 1 | hot water circuit 2 |
Temperature range Water |
30°C up to 90°C | 100°C up to 160°C |
Temperature control | 2 self-optimizing, electronic microprocessor controllers MP-888 with digital display of the set and actual value. Automatic temperature monitoring. |
|
Flow control | electronically, with digital display and automatic control of the minimum flow. | |
Heating capacity | 6 kW | 12 kW |
Cooling capacity | approx. 200 kW at 90°C | approx. 80 kW at 160°C |
Pump capacity Pressure mode |
motor 1,8 kW max. 6,5 bar / max. 75 l/min. |
motor 1,8 kW max. 6,5 bar / max. 75 l/min. |
Pressure increasing pump | yes | yes |
Temperature measurement at the mould | no | no |
Pressure discharge and mould drain | yes | yes |
Leakstopper | no | no |
Filling | automatic | automatic |
Connections Medium Cooling water Compressed-air |
3/4” BSP female thread 1” BSP male thread 1/4” BSP female thread |
|
Dimensions | 1’300 × 480 × 1’400 mm, incl. castors | |
Weight | approx. 245 kg empty | |
Colour | silvergrey RAL 7001 |
The heat-up and cool-down times are depending on the mould weight.
The unit TT-30/160 is designed for a mould weight up to 500 kg.
The fastest cycle time can be achieved with small moulds.
Sufficiently large form channels are also important.
Faster times can be achieved if each mould half is equiped with a separate unit
There are no reviews yet.