TECHNICAL DATA: | TT-137 N | TT-137 B/BP | ||
Temperature range | up to 140°C | up to 160°C | ||
Temperature control | Self-optimizing, electronic microprocessor controller MP-888 with digital display of the set and actual value. Automatic temperature monitoring. |
|||
Heating capacity Switchable in stages |
12 kW 6 / 6 |
12 kW 6 / 6 |
||
Cooling capacity Indirect Direct |
approx. 90 kW at 160°C approx. 60 kW at 50°C |
|||
Pump capacity Pressure mode Vacuum mode Model |
motor 1,8 kW max. 5 bar / max. 110 l/min. vacuum max. 8 mH2O axial face seal |
motor 1,8 kW max. 6,5 bar / max 75 l/min vacuum max. 8 mH2O seal less magnetic drive |
||
Pressure increasing pump | no | yes | ||
Temperature measurement at the mould | yes | yes | ||
Pressure discharge | yes | yes | ||
Leakstopper and mould drain | with compressed-air | with compressed-air | ||
Filling | automatic | automatic | ||
Connections Medium Cooling water Compressed-air |
3/4″ BSP female thread 3/8″ BSP male thread, inlet with water filter 3/8″ BSP female thread 1/4″ BSP female thread |
|||
Dimensions (LxWxH) | 870 × 360 × 915 mm, incl. castors | |||
Weight | approx. 120 kg empty | |||
Colour | silvergrey RAL 7001 |
Options:
MP-988 Microprocessor Controller for Digital Interfaces (RS-485 / RS-232 / Current Loop 20mA / CAN-bus / Profibus)
All possible voltages are available from 3 x 200 V to 3 x 600 V and 50/60 Hz.
The units are available conform to UL/CSA specifications. For the USA market the units are equipped with NPT-thread connections and the controller is adjusted to indicate °F